What each line of a sale chimney report is telling you
Book a sale inspection
Give us the property address and the names that should get copies. We reply with a visit time.
A sample page, marked up
Here is the first page of a typical report from a Costa Mesa sale, with notes on how to read it. The house is a 1960s single story with a wood insert set into the original brick fireplace. The sellers burned through last winter, and the general inspector wrote one line about the chimney: refer to a specialist.
Read the summary first. It is one sentence on whether the chimney is fit to burn as it stands. Then read the findings, which are always in the same order, worst first, each with the photo numbers that show it.
- Header: address, visit date, Level 2, and the appliance found. Here, a wood insert in a masonry fireplace.
- Summary: not fit to burn until finding 1 is corrected.
- Finding 1, before the next fire: liner ends two feet above the insert collar, so smoke spills into the old smoke chamber. Photos 3 and 4.
- Finding 2, soon: crown cracked in two places, cap screen rusted thin. Photos 9 and 10.
- Finding 3, no action: light soot, tiles intact above the liner end. Photos 5 to 8.
- Back page: what we could not see and why, such as an attic corner blocked by stored furniture.
The flue pages: reading the camera stills
Each still is labeled with its height, measured down from the top of the chimney. A thin dry layer of soot is normal for a house where wood has been burned. Thick, bubbly or shiny black tar is not, and the caption will say which stage we saw, because heavy tar points to wet wood, a slow stove or a flue far too big for the appliance.
Cracks and open joints get their own stills. A hairline in a single tile reads differently from a joint that has opened a finger's width. The caption says which, and whether a liner, a repair or nothing is the usual answer.
The appliance page: stove, insert or open hearth
Houses that burn wood get an extra page. For a stove or insert we note the label plate if it can be read, the distance to walls, trim and the mantel, the floor pad, the door and glass seals, the firebrick and how the stove connects to the chimney. For an open fireplace we cover the firebox, the damper and the hearth in front of it.
This is the page buyers of a wood burning house tend to skip and should not. A stove that looks fine in the living room can be venting into an old open fire flue with nothing but a short pipe, and that one finding often matters more than anything on the roof.
What the report means for the deal
We do not take a side. The report says what we saw, where, and what it means for using the fireplace. A buyer can carry a before-the-next-fire finding into a repair request. A seller who sees the same finding can fix it ahead of time and hand the buyer a clean report instead.
Neither side needs us to do the repair. If someone wants a figure, it comes as a separate written quote, so the inspection document stays a plain record of the chimney on the day of the visit.
Sale inspection prices
Most sales call for the camera visit. The visual check is listed for owners who are staying put and want a basic look.
- Level 2 for a sale, camera run and photo report included
- $385
- Visual Level 1 for a house that is not changing hands
- $165
Repairs that come up in a report have their own written figures. The common ones with set prices are listed on our up-to-code repairs page.
Questions about sale reports
Who receives the report?
Whoever books gets it, along with anyone named at booking: the other agent, the seller, a lender. Every copy is the same document with the same photos.
Can a chimney fail a house?
There is no pass or fail. Each item is sorted into before the next fire, soon, or no action. What happens next is up to the buyer and seller.
The home inspector wrote further evaluation. Is this that?
Yes. With that note the house inspector passes the flue and stove over to a chimney specialist, and a Level 2 is the evaluation it asks for.
Does the report say whether the stove was permitted?
No. We report what we see against the stove maker's clearances and how the stove vents. Permit history comes from the city's records.
Should the buyer attend?
Buyers are welcome, but it is not needed. Access usually runs through the agents, and the numbered photos show everything we looked at.
What if the sellers lit a fire the night before?
We need the fire out and the ash cold. A hot stove cannot be opened, and the camera cannot run through a flue full of heat. Ask the sellers to let it go out a day ahead.
Get the report your sale needs
Send the property address and the names of everyone who needs a copy through the contact page. We book the camera visit and deliver one report to all of them.
Call (949) 879-2621